Skip to content
WeighModulesRequest a quote

Mechanical retrofit center

SWB505, Rice Lake & Anyload Weigh Module Retrofits

Measure the installed working height and both plate interfaces. Send the exact model, rating and revision for a replacement drawing review.

Request a kit review ↗

Original assembly heights by model and rating

Use this table to identify the required original drawing. Dry-fit and operating stack heights may differ with transit hardware, pads and shims.

Existing modulePublished assembly height HSource
SWB505 MultiMount, 110 kg–1.1 t105.2 mm active; 106.8 mm locked; 130.6 mm with padOriginal reference
SWB505 MultiMount, 4.4 t136.6 mm active; 138.1 mm locked; 162.0 mm with padOriginal reference
SWC515 / SWC515-A PinMountUse the exact capacity and drawing revisionOriginal reference
EZ Mount 1 HE stainless, 5,000–20,000 lb5.31 in (≈134.9 mm) nominalOriginal reference
EZ Mount 1 HE stainless, 30,000–60,000 lb8.43 in (≈214.1 mm) nominalOriginal reference
RL1855 HE-HS, 1,000–4,000 lb5.25–5.56 in (≈133.4–141.2 mm)Original reference
RL1855 HE-HS, 5,000–10,000 lb6.12–6.62 in (≈155.4–168.1 mm)Original reference
Anyload tank or hopper weigh moduleUse the original SKU and capacity drawingOriginal reference

What the replacement drawing must match

InterfaceField measurements and requirements
Top plate A × BHole-center spacing on each axis, count, diameter or thread, and offset from the load center.
Base plate A × BHole-center spacing, plate and beam edge clearances, anchor type and mounting face condition.
Installed height HBearing-face to bearing-face distance in service, including shim or pad thickness.
Uplift and side load (kN)Rated and design values with load direction, sign and applicable load combination.
Pin and restraint orientationPhotograph each support and label the datum, permissible travel and extraction direction.

After measurement, confirm the proposed WMD interface and capacity on the drawing before ordering. Manufacturer names identify the existing equipment.