Weigh Module Buying Guide & Comparison

Start with the vessel’s load cases and support layout. Then choose the mount, allowable travel and cleaning specification.

Request a kit review ↗

Compare the load cases before selecting a mount

Selection variableStatic / sliding pinAgitator / restrainedHygienic / washdown
Operating loadStorage and controlled dischargeTorque, vibration and transient loadsConfirm mixing duty independently
Installation locationDry indoor or project-specific outdoor hardwareDimension restraints and anchors for external loadsReview water, chemical and cable exposure
Jacketed or heated vesselAlign guided travel with vessel growthVerify rod geometry through heat-up and coolingReview thermal cycling during CIP
CleaningStandard enclosure for the dutyInspect rod ends and any exposed cavitiesSpecify 316L, drainage and the exact sealing requirements
Gross load(Empty tare + maximum product) ÷ support count × 1.5 for a first capacity screen

For a 12,000 kg vessel on four supports, the average is 3,000 kg and the preliminary minimum is 4,500 kg per support. Compare the result with the peak measured or calculated reaction before selecting a rated cell.

Check cold-to-hot travel at the mount

Estimate free expansion with ΔL = α × L × ΔT, using the distance from the installation’s fixed datum along the relevant travel direction. For a 2 m steel span at an illustrative 12 µm/(m·°C) over a 40 °C rise, free movement is about 0.96 mm. Allow for installation tolerance, frame movement, piping reactions and travel in both directions.