Selection guide
Weigh Module Buying Guide & Comparison
Start with the vessel’s load cases and support layout. Then choose the mount, allowable travel and cleaning specification.
Request a kit review ↗Compare the load cases before selecting a mount
| Selection variable | Static / sliding pin | Agitator / restrained | Hygienic / washdown |
|---|---|---|---|
| Operating load | Storage and controlled discharge | Torque, vibration and transient loads | Confirm mixing duty independently |
| Installation location | Dry indoor or project-specific outdoor hardware | Dimension restraints and anchors for external loads | Review water, chemical and cable exposure |
| Jacketed or heated vessel | Align guided travel with vessel growth | Verify rod geometry through heat-up and cooling | Review thermal cycling during CIP |
| Cleaning | Standard enclosure for the duty | Inspect rod ends and any exposed cavities | Specify 316L, drainage and the exact sealing requirements |
| Gross load | (Empty tare + maximum product) ÷ support count × 1.5 for a first capacity screen | ||
For a 12,000 kg vessel on four supports, the average is 3,000 kg and the preliminary minimum is 4,500 kg per support. Compare the result with the peak measured or calculated reaction before selecting a rated cell.
Check cold-to-hot travel at the mount
Estimate free expansion with ΔL = α × L × ΔT, using the distance from the installation’s fixed datum along the relevant travel direction. For a 2 m steel span at an illustrative 12 µm/(m·°C) over a 40 °C rise, free movement is about 0.96 mm. Allow for installation tolerance, frame movement, piping reactions and travel in both directions.